ZHANG Hongyan, SHI Erbing, FANG Chengyue. Design factors analyses of second-loop PRHRS[J]. Chinese Journal of Ship Research, 2017, 12(3): 98-104. DOI: 10.3969/j.issn.1673-3185.2017.03.014
Citation: ZHANG Hongyan, SHI Erbing, FANG Chengyue. Design factors analyses of second-loop PRHRS[J]. Chinese Journal of Ship Research, 2017, 12(3): 98-104. DOI: 10.3969/j.issn.1673-3185.2017.03.014

Design factors analyses of second-loop PRHRS

  • In order to study the operating characteristics of a second-loop Passive Residual Heat Removal System (PRHRS), the transient thermal analysis code RELAP5 is used to build simulation models of the main coolant system and second-loop PRHRS. Transient calculations and comparative analyses under station blackout accident and one-side feed water line break accident conditions are conducted for three critical design factors of the second-loop PRHRS:design capacity, emergency makeup tank and isolation valve opening speed. The impacts of the discussed design factors on the operating characteristics of the second-loop PRHRS are summarized based on calculations and analyses. The analysis results indicate that the system safety and cooling rate should be taken into consideration in designing PRHRS's capacity, and water injection from emergency makeup tank to steam generator can provide advantage to system cooling in the event of accident, and system startup performance can be improved by reducing the opening speed of isolation valve. The results can provide references for the design of the second-loop PRHRS in nuclear power plants.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return